Partial capture of text on file.
                              ®
              K-FLEX  } K-FONIK GK/GV
          K-FONIK GK/GV
          SOLID SBR/EVA
                             ®
                 K-FLEX    K-FONIK GK/GV
                                                                                                                                                                                        
                                           Specification                                                       Classification                                                          Notes 
                 UL 50 & 50E                                                          --                                                                   Suitable for enclosure types 2, 3, 3R, 3S, 4, 4X, 5, 6, 6P, 12, 
                                                                                                                                                           12K, and 13, including oil immersion (File #: JMST2.MH60641)
                 UL 94 (K-FONIK GK)                                                   HB                                                                   Listed at 1.2mm (File #: QMFZ2.E300774)
                 ASTM E84                                                             25/50                                                                Pass up to 3mm thickness
                 ASTM E162 (K-FONIK GV)                                                                                                                    Avg. Radiant Panel Index: 2
                 ASTM E662 (K-FONIK GV)                                                                                                                    Corrected Dm: 558
                 IMO A 6553 (K-FONIK GV)                                                                                                                   Approved
                 IMO FTP Code Part 5 (K-FONIK GV)                                                                                                          Approved
                 Wheelmark - MED 36/98/CE (K-FONIK GV)                                                                                                     Approved
                          ®                                                           ®
              The K-FLEX  USA website contains the most recent version of all K-FLEX  USA literature.
                                                                      ®
              Please refer to the website for current versions of K-FLEX  USA literature at www.kflexusa.com
                                                                                                                                                                                               www.kflexusa.com
                                   ®
                K-FLEX  } K-FONIK GK/GV
                                  ®
                    K-FLEX  K-FONIK GK    TECHNICAL DATA
                                                                                                                                                                                                                            
                                                     Property                                                                          Value                                                                     Test method 
                    Polymer                                                                         SBR/EVA
                    Cell structure                                                                  Solid
                    Color                                                                           Black
                    Density                                                                         125 LB/FT3 (±10%)
                    Tensile                                                                         300 PSI Min                                                                      ASTM D412 (DIE A)
                    Elongation                                                                      25% Min                                                                          ASTM D412 (DIE A)
                    Tear Strength                                                                   50 LB/IN Min                                                                     ASTM D624 (DIE C)
                                                                                                    25/50-Rated                                                                      ASTM E84
                    Flammability                                                                    Listed                                                                           UL 94: HBF
                                                                                                    Pass                                                                             FMVSS-302
                                                                                                    Pass                                                                             ASTM D5132
                    Service temperature                                                             -40°F to +158°F
                    Ozone Resistance                                                                Pass                                                                             ASTM D1171
                                                                                                    0.5 LB/FT2: 21 STC (DB)
                    Sound Blocking                                                                  1.0 LB/FT2: 26 STC (DB)                                                          ASTM E90
                                                                                                    1.5 LB/FT2: 29 STC (DB)
                                  ®
                    K-FLEX  K-FONIK GV    TECHNICAL DATA
                                                                                                                                                                                                                            
                                                     Property                                                                          Value                                                                     Test method 
                    Polymer                                                                         SBR/EVA
                    Cell structure                                                                  Solid
                    Color                                                                           Gray
                    Density                                                                         125 LB/FT3 (±10%)
                    Tensile                                                                         300 PSI Min                                                                      ASTM D412 (DIE A)
                    Elongation                                                                      10% Min                                                                          ASTM D412 (DIE A)
                    Tear Strength                                                                   50 LB/IN Min                                                                     ASTM D624 (DIE C)
                                                                                                    25/50-Rated                                                                      ASTM E84
                                                                                                    Pass                                                                             FMVSS-302
                    Flammability                                                                    Pass                                                                             ASTM D5132
                                                                                                    Avg. radiant panel index: 2                                                      ASTM E162
                                                                                                    Corrected DM: 558                                                                ASTM E662 (Flaming exposure)
                    Service temperature                                                             -40°F to +158°F
                    Ozone Resistance                                                                Pass                                                                             ASTM D1171
                                                                                                    0.5 LB/FT2: 21 STC (dB)
                    Sound Blocking                                                                  1.0 LB/FT2: 26 STC (dB)                                                          ASTM E90
                                                                                                    1.5 LB/FT2: 29 STC (dB)
                                  ®
                    K-FLEX  K-FONIK GK/GV    RANGE
        ta and technical requirements without notice.                                                                                                                                                                               
                                       Mass                                  Thickness* Min (mm)                            Thickness* Max (mm)                                      Width                                          Length 
                             2
                    0.5 lb/ft                                       0.8                                            1.2                                             48": +/-2%                                     50': -1.5% / +5%
                             2                                      2.2                                            2.6                                             48": +/-2%                                     50': -1.5% / +5%
                    1.0 lb/ft
                             2
                    1.5 lb/ft                                       3.45                                           3.85                                            48": +/-2%                                     25': -1.5% / +5%
        ves the right to change da*Sheet Thickness should be checked using a calibrated caliper.
         reser
       ®
         US_LEA_K-FONIK GK-GV_V1_0619; K-FLEX
        .
       ®
        © K-FLEX
                                                          K-FLEX USA LLC 
                                                          100 K-FLEX Way, Youngsville, NC 27596
                                                          Phone: 800-765-6475
                                                          info@kflexusa.com                                                                                                                                                   www.kflexusa.com
The words contained in this file might help you see if this file matches what you are looking for:

...K flex fonik gk gv solid sbr eva specification classification notes ul e suitable for enclosure types r s x p and including oil immersion file jmst mh hb listed at mm qmfz astm pass up to thickness avg radiant panel index corrected dm imo a approved ftp code part wheelmark med ce the usa website contains most recent version of all literature please refer current versions www kflexusa com technical data property value test method polymer cell structure color black density lb ft tensile psi min d die elongation tear strength in c rated flammability hbf fmvss service temperature f ozone resistance stc db sound blocking gray flaming exposure range ta requirements without notice mass max...

no reviews yet
Please Login to review.