                 Topics for Discussion
              • Brief history
              • Dynamics of fire
              • What do the codes say?
              • How are they tested?
              • How testing is affecting design
         Saving Lives and Property
         Through Fire and Smoke Containment                      ©2004 IFC
                     Curtain Walls 
                                      &
               the Perimeter Joint
         Saving Lives and Property
         Through Fire and Smoke Containment                      ©2004 IFC
                   A Brief History of Fires 
                   -Where Curtain Wall or 
                 Safing Issues Have Been 
                                  Cited…
         Saving Lives and Property
         Through Fire and Smoke Containment                      ©2004 IFC
         Unsealed or Improperly sealed perimeter 
         joints cost lives and huge liability losses…
         • Summerland, Isle of Man, British Isles.  Fire spread 
            through safing slot.  50 people killed.
         • Hilton Hotel, Las Vegas, NV.  Fire spread from  8th to 13th 
            floor in 25 minutes. 8 fatalities.
         • First Interstate Bank, Los Angeles, CA.  Flames spread 
            from 13th to 16th floor via perimeter joint.  One death.
         • One Meridian Plaza, Philadelphia, PA.  Fire spread from 
              nd     th
            22  to 30  floor through unprotected openings including 
            slab edge.
          Saving Lives and Property
          Through Fire and Smoke Containment                           ©2004 IFC
                    What are the 
          dynamics of vertical 
         spread in a high-rise 
                          building?
         Saving Lives and Property
         Through Fire and Smoke Containment                      ©2004 IFC
The words contained in this file might help you see if this file matches what you are looking for:

...Topics for discussion brief history dynamics of fire what do the codes say how are they tested testing is affecting design saving lives and property through smoke containment ifc curtain walls perimeter joint a fires where wall or safing issues have been cited unsealed improperly sealed joints cost huge liability losses summerland isle man british isles spread slot people killed hilton hotel las vegas nv from th to floor in minutes fatalities first interstate bank los angeles ca flames via one death meridian plaza philadelphia pa nd unprotected openings including slab edge vertical high rise building...