172x Filetype PDF File size 1.64 MB Source: eia.emb.gov.ph
PROJECT DESCRIPTION FOR SCOPING 300 MW Diesel Power Plant Project Ingrid2 Power Corporation Barangay Batangas II, Mariveles, Bataan Submitted to: Environmental Management Bureau – Central Office February 2020 • An Environmental Report By: Unit 8L-M, Future Point Plaza 3 111 Panay Avenue, South Triangle Rizal City, Metro Manila Tel. No.: (02) 442-2830 Submitted To: Department of Environment and Natural Resources Environmental Management Bureau – Central Office EMB Building, DENR Compound, Visayas Avenue Diliman, Quezon City DOCUMENT TRACKING Versio Report Compiled By: Checked By: Approved By: n No. Name Signature Name Signature Date 1 K.G. Bartolome J.M. Lim J.M. Lim Distribution of Latest Version No. of Submitted To: Date Submitted Received By: Remarks: Copies February 2020 Table of Contents 1.0 PROJECT DESCRIPTION ................................................................................................... 1-1 1.1 Project Location and Area ....................................................................................... 1-2 1.1.1 Accessibility of the Project Site ...................................................................................................... 1-2 1.1.2 Project Impact Areas ...................................................................................................................... 1-2 1.2 Project Rationale .................................................................................................... 1-8 1.3 Project Alternatives ................................................................................................ 1-9 1.3.1 Site Selection .................................................................................................................................. 1-9 1.3.2 Technology/Design Selection ......................................................................................................... 1-9 1.3.3 Resources ....................................................................................................................................... 1-9 1.4 Project Components.............................................................................................. 1-11 1.5 Process/Technology .............................................................................................. 1-12 1.5.1 Major Components: Modular Diesel Generators ......................................................................... 1-12 1.5.2 Auxiliary Facilities ......................................................................................................................... 1-13 1.5.3 Pollution Control Facilities ........................................................................................................... 1-13 1.5.4 Plant Operation and Maintenance ............................................................................................... 1-14 1.6 Project Size ........................................................................................................... 1-14 1.7 Development Plan, Description of Project Phases, and Corresponding Timeframes . 1-15 1.7.1 Pre-Construction .......................................................................................................................... 1-15 1.7.2 Construction ................................................................................................................................. 1-15 1.7.3 Operation ..................................................................................................................................... 1-15 1.7.4 Decommissioning/Abandonment/Rehabilitation ........................................................................ 1-15 1.8 Manpower ............................................................................................................ 1-17 1.9 Project Cost .......................................................................................................... 1-17 1.10 Preliminary Identification of Environmental Impacts .............................................. 1-17 Table of Tables Table 1-1: Basic Information on the Proposed Project, Proponent, and EIA Preparer ................................... 1-1 Table 1-2: Landmarks and Structures Adjacent to the Proposed Project Site ................................................ 1-2 Table 1-3: Area Allocation of the Proposed Project Components ................................................................ 1-11 Table 1-4: Tentative Project Development and Implementation Timeline .................................................. 1-16 Table 1-5: Manpower Requirement per Project Phase ................................................................................ 1-17 Table of Figures Figure 1-1: Vicinity Map of the Proposed Project Site ................................................................................... 1-4 Figure 1-2: Technical Coordinates of the Proposed Project Site ........................... Error! Bookmark not defined. Figure 1-3: Accessibility Map of the Proposed Project Site ............................................................................ 1-5 Figure 1-4: Aerial Photograph of the Proposed Project Location ................................................................... 1-6 Figure 1-5: Direct and Indirect Impact Areas of the Proposed Project ........................................................... 1-7 Figure 1-6: Modular Diesel Power Plant Technology ................................................................................... 1-10 Figure 1-7: Plant Layout Plan for the Proposed Project ........................................ Error! Bookmark not defined. Figure 1-8: General Site Layout Plan for the Proposed Project ............................. Error! Bookmark not defined. INGRID2 POWER CORPORATION 300-MW DIESEL POWER PLANT PROJECT Brgy. Batangas II, Mariveles, Bataan PROJECT DESCRIPTION FOR SCOPING 1.0 PROJECT DESCRIPTION Ingrid2 Power Corporation (the “Proponent”) will be developing a 300 MW modular diesel engine power plant (the “Generation Facility”) in Barangay Batangas II, Mariveles, Bataan. The Generation Facility will be composed of multiple modular diesel engine units and is planned to be connected via an approximately 1-kilometer transmission line to TeaM Energy’s 230 kV Bataan Substation which is directly connected to the NGCP 230 kV Limay Substation. The Proponent is required to secure an Environmental Compliance Certificate (ECC) from the DENR-EMB prior to any development in the project site. Pre-requisite to the acquisition of an ECC for a project of this scale is the preparation of an Environmental Impact Statement (EIS), as stated in Annex A Item No. 3.2.4 (Other Thermal Power Plants e.g., coal, diesel, bunker, etc. with total power generating capacity equal to or greater than 30 MW) of the EMB Memorandum Circular 005-2014 (“Revised Guidelines for Coverage Screening and Standardized Requirements under the Philippine EIS System”). Table 1-1 provides some basic information regarding the proposed project, the Proponent, and the Environmental Impact Assessment (EIA) preparer. Table 1-1: Basic Information on the Proposed Project, Proponent, and EIA Preparer Project Name 300 MW Diesel Power Plant Project Project Location Brgy. Batangas II, Mariveles, Bataan Project Area 6 hectares Project Type Diesel-Fired Power Plant Project Size/Capacity 300 megawatts INGRID2 Power Corporation Office Address: 4/F, 6750 Office Tower, Ayala Avenue, Ayala Center, Makati City Project Proponent Tel. No.: (02) 7730-6300 Authorized Representative: Atty. Rodrigo M. San Pedro, Jr. (Attorney-In-Fact) LCI Envi Corporation Office Address: Unit 8L-M, Future Point Plaza 3, 111 Panay Avenue, South Triangle, Quezon City EIA Preparer Tel. No.: (02) 8442-2830 / Fax No.: (02) 8961-9226 Authorized Representative: Engr. Jose Marie U. Lim (EIA Team Leader) 1-1
no reviews yet
Please Login to review.